110V Transformers Explained: Why UK Sites Use Them and Which Size You Need

´

A 110V transformer steps UK mains power down from 230V to 110V so that power tools, lighting and small machinery can be used safely on construction sites. If you have ever seen a yellow box with a thick lead and yellow sockets on a building site, that is a 110V site transformer, and under HSE guidance it is the standard way to run portable tools on most UK sites.

This guide explains why the UK settled on 110V, the difference between the main types of 110 transformers, how to work out what size you need, and what to look for when buying one.

110V tool and site transformer

Why UK building sites use 110V

Standard UK mains is 230V. A fault on a 230V tool, a cut cable or a drill through a flex can put the full 230V through whoever is holding it. Sites are wet, muddy and full of sharp edges, so the risk of that happening is far higher than at home.

A 240V to 110V transformer removes most of that risk. The 110V output is centre-tapped to earth, which means each live conductor sits at only 55V relative to earth. A shock at 55V is far less likely to be fatal than one at 230V. That is why the HSE recommends reduced low voltage (110V CTE) for portable tools on construction sites, and why most principal contractors make it a site rule.

The transformer is the piece of kit that makes this possible. It takes the 230V supply in, steps it down to 110V, and gives you yellow 16A or 32A sockets to plug tools into. Everything on the 110V side of the box is protected by the lower voltage. Airlink builds every tool and site transformer in the UK to BSEN61558, in a reinforced case designed to survive a site.

Types of 110V transformer

Not every 110V transformer is the same. The right one depends on how many tools you are running, how long they run for, and where the transformer will live.

110V portable tool transformer

Portable tool transformers. The yellow box most people picture: 1.5kVA to 3.3kVA, carried to where the work is, plugged into a 230V socket and running one or two tools at a time. Right for most trades. See the range.

110V site transformer

Site transformers. Larger fixed or semi-fixed units from 5kVA to 15kVA that feed a whole area of the site, usually from a 400V or 230V supply, with several outlets for multiple tools and lighting at once. A 5kVA transformer is the common choice for a small site; 10kVA and 15kVA for larger ones. See the range.

Heavy duty 110V portable transformer

Heavy duty portable transformers. Continuously rated units for tools that run for long stretches: breakers, cutters, mixers. A standard portable transformer is rated for intermittent use; if a tool is running all day, this is the one you need. See the range.

230V portable tool transformer

230V and low voltage portable transformers. Isolating transformers that keep the voltage at 230V but electrically separate the tool from the mains, and 24V or 42V units for inspection lamps and extra-low-voltage tools in confined or wet spaces. 230V range and 24V/42V range.

What size 110V transformer do I need?

Transformers are rated in VA (volt-amps), which for this purpose you can treat as watts. Add up the wattage of everything that will run from the transformer at the same time, then pick a transformer rated above that total. Running a transformer at or over its rating will trip it or blow fuses, and tools with motors draw a surge at start-up well above their running wattage.

ToolTypical ratingTransformer needed (single tool)
Cordless charger / inspection lamp100 to 300W1kVA
Drill / jigsaw / sander600 to 900W1.5kVA
Angle grinder (9 inch)2,000 to 2,400W3kVA
SDS drill / breaker1,100 to 1,700W3kVA
Circular saw / chop saw1,600 to 2,200W3kVA
Cement mixer500 to 750W (high start-up)3kVA
Site lighting (4 x 500W)2,000W3kVA
Several tools at once across a site4,000W+5kVA or larger site transformer

Two rules of thumb: a 3kVA portable transformer covers one heavy tool or two light ones; a 5kVA site transformer is the starting point when more than one person is working from the same box. If in doubt, size up. The figures above are a guide, so always check the rating plate on the tool itself.

What to check before you buy

  • Duty rating. Tool-rated transformers are designed for intermittent use (typically 50% duty). For tools that run continuously, choose a continuously rated or heavy-duty unit.
  • Input connection. Standard UK 13A plug for small units; 16A or 32A blue CEE plug for larger ones and for sites fed from a distribution board. Check what your supply gives you.
  • Outlets. Count how many 16A and 32A yellow sockets you need. Most portable units have two 16A; site transformers have more, often with a 32A outlet.
  • Case. A GRP (fibreglass) case is tough, non-conductive and handles weather better than steel on an open site.
  • Thermal protection. A thermal cut-out protects the transformer if it is overloaded or covered. All Airlink site units have it as standard.
  • Standards. Look for BSEN61558 and CE marking. Airlink transformers are built and tested in the UK to this standard.

Frequently asked questions

Is a 110V transformer the same as a transformer box?

Yes. "Transformer box" is just the everyday name for a site or tool transformer in its case.

Can I run 110V tools at home?

Yes. A small portable tool transformer plugs into a normal 13A socket, so site tools can be used anywhere there is mains power.

Can I leave a site transformer switched on?

Yes. Off-load it draws very little current. Keep it ventilated and off soft ground so it can shed heat.

Does the transformer change the frequency?

No. UK mains is 50Hz in and 50Hz out. The transformer only changes the voltage.

>